How do I stop a 2CE error code?
The beam sensor may not be aligned correctly, (both the green and red lights on the top of the sensor, on at the same time indicate proper alignment). Move/adjust the sensor or the reflector in order to line them up and ensure both lights are lit.

On TEHX or TMEX Machines if the beam sensor is properly aligned (see above) then check the emergency stop button; turn it to the right to release